Designed for the most critical material storage.
- Safer, more convenient than LN2— systems—lower operating costs, too.
- Maintain uniform temperatures of -140° and -150°C, safely below the -130°C glass transition temperature of water.
- Top-to-bottom temperature uniformity is dramatically improved when compared to LN2 vapor.
- Cell viability is improved because biologically relevant, thermally driven reactions are not known to occur.
- Manual defrost
Compliance: UL, cUL listed.
Part Number |
Description |
ULT10140-9-D |
-140C; 10.3 cu. ft.; 208/230V 60Hz |
ULT10140-9-V |
-140C; 10.3 cu. ft.; 230V 50Hz |
ULT10140-9-E |
-140C; 10.3 cu. ft.; 208/230V 60Hz, 3A |
ULT10140-9-M |
-140C; 10.3 cu. ft.; 380V 50Hz, 3A |
ULT10140-9-R |
-140C; 10.3 cu. ft.; 200V 50Hz, 3A |
ULT7150-9-D |
-150C; 193L; 208/230V 60Hz |
ULT7150-9-E |
-150C; 193L; 208/230V 60Hz, 1A |
ULT7150-9-M |
-150C; 193L; 380V 50Hz, 3A |
ULT7150-9-R |
-150C; 193L; 200V 50Hz, 3A |
ULT7150-9-V |
-150C; 193L; 230V 50Hz, 1A |
Refrigeration System
- Exclusive mixed refrigerant autocascade with a single, orbital air-cooled compressor
- Downfeed evaporator
- High-capacity air-cooled condenser with dual condenser fans
- Washable condenser filter
IntrLogic Microprocessor Control System
- Touchpad data entry with digital display of all functions
- Key-operated main power and alarm switch for setpoint security
- Setpoints adjustable in 1°C increments
- Independent operating temperature and high/low limit alarm functions
Alarm System
- Power failure or temperature deviation triggers audible and visual warning
- Automatic Incident Monitor identifies temperature deviation beyond alarm setpoints
- Adjustable safety alarm with automatic, continuous charge battery backup
- Digital battery indicator
- Touchpad alarm test function
- RS-232 data port with system software
- Exterior alarm contacts for connection to remote monitoring system
Monitoring System
- Lifeguard compressor protection monitors performance and automatically adjusts to internal and external conditions
- Extreme Ambient Alert warns if room temperature can affect performance
- Voltage Boost Indicator advises of low source voltage below safe parameters and indicates voltage boost system is activated
- On-board power monitoring with digital readout of incoming line voltage
- Built-in surge suppressor
- "Clean Filter" indicator
Construction
- Low-profile design for easy access to inventory
- Heavy-gauge steel cabinet with high-impact powder paint finish
- Heavy-duty counterbalanced lid with integrated keyed lock and independent sublids
- Double-seal lid gaskets minimize frost buildup
- Minimum 5 in. (12.7cm) foamed-in-place closed-cell, CFC-free urethane insulation
- Access port, 1 in. (2.54cm) diameter, with cap
- Recessed heavy-duty swivel casters
Uses standard Thermo Scientific Revco inventory racks and fiberboard boxes, available separately.
Control |
Microprocessor |
Defrost |
Manual |
Refrigeration System |
High-capacity, air-cooled autocascade |
Refrigerant |
CFC-Free |
Compressor |
1, with Lifeguard Protection Systems |
Cabinet |
Heavy-gauge steel with high-impact powder paint finish |
Lids |
Heavy-duty counterbalanced lid with integrated keyed lock and insulated sublids |
Port(s) |
One 1 in. (2.54cm) dia. access, with cap |
Cat. No. |
Capacity |
Electrical Requirements |
Holds |
Phase |
Temperature Range |
ULT10140-9-D |
292L |
208/230V 60Hz 1P |
19,800 x 2 in. vials |
Single |
-140°C |
ULT10140-9-V |
292L |
230V 50Hz 1P |
19,800 x 2 in. vials |
Single |
-140°C |
ULT10140-9-E |
292L |
208/230V 60Hz 3P |
19,800 x 2 in. vials |
Three |
-140°C |
ULT10140-9-M |
292L |
380V 50Hz 3P |
19,800 x 2 in. vials |
Three |
-140°C |
ULT10140-9-R |
292L |
200V 50Hz 3P |
19,800 x 2 in. vials |
Three |
-140°C |
ULT7150-9-D |
193L |
208/230V 60Hz 1P |
13,200 x 2 in. vials |
Single |
-150°C |
ULT7150-9-E |
193L |
208/230V 60Hz 3P |
13,200 x 2 in. vials |
Three |
-150°C |
ULT7150-9-M |
193L |
380V 50Hz 3P |
13,200 x 2 in. vials |
Three |
-150°C |
ULT7150-9-R |
193L |
200V 50Hz 3P |
13,200 x 2 in. vials |
Three |
-150°C |
ULT7150-9-V |
193L |
230V 50Hz 1P |
13,200 x 2 in. vials |
Single |
-150°C |
|