Mandel Hopmepage
HomeTo Order
  General Lab EquipmentBalancesCentrifugesCryogenicsFreezers and RefrigeratorsFume HoodsHomogenizersRadiation SafetyShakers, Stirrers, VortexesSonicatorsSterilizersTemperature RegulationWashers and DryersWater and Dry BathsWater PurificationGloves
   

Revco Ultima II Series Cryogenic Storage Chest Freezers

Thermo
  • Designed for the most critical material storage.
  • Safer, more convenient than LN2— systems—lower operating costs, too.
  • Maintain uniform temperatures of -140° and -150°C, safely below the -130°C glass transition temperature of water.
  • Top-to-bottom temperature uniformity is dramatically improved when compared to LN2 vapor.
  • Cell viability is improved because biologically relevant, thermally driven reactions are not known to occur.
  • Manual defrost 

Compliance: UL, cUL listed.

Part Number

Description

ULT10140-9-D

-140C; 10.3 cu. ft.; 208/230V 60Hz

ULT10140-9-V

-140C; 10.3 cu. ft.; 230V 50Hz

ULT10140-9-E

-140C; 10.3 cu. ft.; 208/230V 60Hz, 3A

ULT10140-9-M

-140C; 10.3 cu. ft.; 380V 50Hz, 3A

ULT10140-9-R

-140C; 10.3 cu. ft.; 200V 50Hz, 3A

ULT7150-9-D

-150C; 193L; 208/230V 60Hz

ULT7150-9-E

-150C; 193L; 208/230V 60Hz, 1A

ULT7150-9-M

-150C; 193L; 380V 50Hz, 3A

ULT7150-9-R

-150C; 193L; 200V 50Hz, 3A

ULT7150-9-V

-150C; 193L; 230V 50Hz, 1A


Refrigeration System

  • Exclusive mixed refrigerant autocascade with a single, orbital air-cooled compressor
  • Downfeed evaporator
  • High-capacity air-cooled condenser with dual condenser fans
  • Washable condenser filter

IntrLogic Microprocessor Control System

  • Touchpad data entry with digital display of all functions
  • Key-operated main power and alarm switch for setpoint security
  • Setpoints adjustable in 1°C increments
  • Independent operating temperature and high/low limit alarm functions

Alarm System

  • Power failure or temperature deviation triggers audible and visual warning
  • Automatic Incident Monitor identifies temperature deviation beyond alarm setpoints
  • Adjustable safety alarm with automatic, continuous charge battery backup
  • Digital battery indicator
  • Touchpad alarm test function
  • RS-232 data port with system software
  • Exterior alarm contacts for connection to remote monitoring system

Monitoring System

  • Lifeguard compressor protection monitors performance and automatically adjusts to internal and external conditions
  • Extreme Ambient Alert warns if room temperature can affect performance
  • Voltage Boost Indicator advises of low source voltage below safe parameters and indicates voltage boost system is activated
  • On-board power monitoring with digital readout of incoming line voltage
  • Built-in surge suppressor
  • "Clean Filter" indicator

Construction

  • Low-profile design for easy access to inventory
  • Heavy-gauge steel cabinet with high-impact powder paint finish
  • Heavy-duty counterbalanced lid with integrated keyed lock and independent sublids
  • Double-seal lid gaskets minimize frost buildup
  • Minimum 5 in. (12.7cm) foamed-in-place closed-cell, CFC-free urethane insulation
  • Access port, 1 in. (2.54cm) diameter, with cap
  • Recessed heavy-duty swivel casters

Uses standard Thermo Scientific Revco inventory racks and fiberboard boxes, available separately.


Control

Microprocessor

Defrost

Manual

Refrigeration System

High-capacity, air-cooled autocascade

Refrigerant

CFC-Free

Compressor

1, with Lifeguard Protection Systems

Cabinet

Heavy-gauge steel with high-impact powder paint finish

Lids

Heavy-duty counterbalanced lid with integrated keyed lock and insulated sublids

Port(s)

One 1 in. (2.54cm) dia. access, with cap

 

Cat. No.

Capacity

Electrical Requirements

Holds

Phase

Temperature Range

ULT10140-9-D

292L

208/230V 60Hz 1P

19,800 x 2 in. vials

Single

-140°C

ULT10140-9-V

292L

230V 50Hz 1P

19,800 x 2 in. vials

Single

-140°C

ULT10140-9-E

292L

208/230V 60Hz 3P

19,800 x 2 in. vials

Three

-140°C

ULT10140-9-M

292L

380V 50Hz 3P

19,800 x 2 in. vials

Three

-140°C

ULT10140-9-R

292L

200V 50Hz 3P

19,800 x 2 in. vials

Three

-140°C

ULT7150-9-D

193L

208/230V 60Hz 1P

13,200 x 2 in. vials

Single

-150°C

ULT7150-9-E

193L

208/230V 60Hz 3P

13,200 x 2 in. vials

Three

-150°C

ULT7150-9-M

193L

380V 50Hz 3P

13,200 x 2 in. vials

Three

-150°C

ULT7150-9-R

193L

200V 50Hz 3P

13,200 x 2 in. vials

Three

-150°C

ULT7150-9-V

193L

230V 50Hz 1P

13,200 x 2 in. vials

Single

-150°C

 

 

  Privacy Policy | Comments