COY’s Most Widely Used Tissue Culture
Glove Box

Perform Incubation, Culture Maintenance and Analysis in the Same Environment
Hypoxic, Normoxic, Physiologic, Hyperoxic

 

Standard Features and Equipment:

  • Automatic Airlock, Temperature Control and Automatic Dehumidifier
  • Control of O2 in 0.1% increments
  • Control of CO2 in 0.1% increments
  • Gloveless sleeves:
    - Operator’s arms and hands may enter the box through a cuff-and-sleeve system without compromising the environment
    - Arm port plugs seal box when operator is not working in it
    - Gloves may be attached to sleeves if there are concerns about potential contamination
  • Patented diaphragm top to compensate for small volume changes, increasing user ergonomic comfort
  • Large side door for initial equipment installation
  • Adjustable interior shelves
  • Interior power supply

Coy’s modular designs and accessories, along with their 40 years of in-house customization experience,
allow them to configure an economical glove box for your lab.

How the O2 and CO2 Control Systems Work

  • With a gas source connected to the controllers, the microprocessors control gas purges based on sensor readings and user-adjustable set points. Typical units for controlling at less than 20.9% O2 will require nitrogen and CO2 sources while units controlling greater than 20.9% O2 will require an O2 source as well.
  • There is a constant LED display of glove box gas levels. The systems, combined with the sealed glove box and airlock, provide a more accurate and uninterrupted environment than an incubator or cabinet system by eliminating exposure to non-experimental conditions.

How the Airlock Works

  • Equipped with a purge-only airlock, which is a transfer chamber that equilibrates O2 levels by purging excess O2 prior to opening the door into the actual glove box and placing items within.
  • Ideal purge times are provided by Coy for various O2 levels.
  • Automatic units use a specific preset time for purges based on protocol and desired glove box O2 levels. Once preset, the airlock is operated with the touch of a button by lab personnel. With manual units, the user operates a valve and times the purge.

How to Control for Heat and Humidity

  • Temperature control up to 40ºC.
  • For long-term incubation (greater than 12 hours), users will want to maintain high humidity levels to prevent samples from drying out. Coy offers a small humidified incubation box that allows samples to be incubated at levels of moisture at or near saturation, while minimizing the amount of moisture that escapes into the glove box.
  • Coy provides two solutions for controlling and removing moisture from the glove box - a desiccant-based system or an automatic dehumidifier.
  • The dehumidifier is an electronic system with digital displays and easy adjustments that free users from
    routine maintenance.
  • The desiccant system involves alumina desiccant contained in a wire mesh and placed over the glove box’s circulation system. The desiccant system is less costly than the dehumidifier option, but to succeed, it requires alert personnel who have an understanding of how the system works.

Key Accessories

CO2 Control System

  • The Coy CO2 Control System allows for precise control and monitoring of CO2 gases inside the glove box.
  • A sensor relays information to the controller, which then opens the appropriate solenoid controlling a CO2 or N2 gas to equilibrate the CO2 levels based on the user-adjustable set point.
  • The digital display allows the user to monitor the CO2 levels constantly.

Microscope View Port

  • Microscopes are easier to use with this optically clear flexible vinyl port.
  • The port is sealed to the box wall and is installed directly over the microscope’s eyepieces, enabling
    easy use of the oculars.
  • Cultures may go directly from incubation to the microscope allowing the researcher to see transient effects that may be lost when imaging and/or media change is done outside of a controlled environment.
  • Custom sizing of glove boxes to fit specific microscopes is available.

Humidified Incubation Box

  • The Coy Humidified Incubation Box for tissue culture is a separate cabinet that sits inside the glove box.
  • Allows cultures to be humidified with the same atmosphere content (gas and temperature) as the glove box without immediately increasing the humidity of the rest of the box.
  • Capacity: 36 x 100 mm petri dishes or well plates can be stored in each unit if stacked two high.
    Size: 12” L x 6” D x 16” H / 305 x 152 x 406 mm. (Custom sizes are available.)

Recirculating Atmosphere Filtration System (HEPA)

  • Filters the box atmosphere and controls contamination through a standard HEPA filter.
  • The external pump-activated system has the filter mounted outside the box.
  • The system draws the internal atmosphere out of the box, through the external filter and back into the box.
  • Equipped with quick disconnect fittings, the filter is fast and easy to change without compromising filter and
    glove box integrity.
  • Other types of filters can be added to meet other filtration needs.

UV Light and UV-Resistant Acrylic Upgrade

  • A combination of fluorescent and 254-nanometer UV lights provides illumination and decontamination of
    the work area.
  • An upgrade of the entire box to UV-resistant acrylic material, which absorbs UV light to protect the user,
    is recommended.

Anoxic Upgrade Kit

  • Coy offers a kit for upgrading O2 Control Glove Boxes to enable the user to create an anoxic environment,
    0-5 parts per million O2, using catalyst reacting with a nonflammable gas mix.

Feed-Thru Adaptor

  • Electrical wiring, tubing or cords are input through factory-installed feed-thru adaptors sealed through the
    glove box wall.

Material and Size Choices
Coy O2 Control Glove Boxes for tissue culture are available in polycarbonate (three standard sizes) and aluminum
(two standard sizes). The choice of material depends on your research needs and budget. Aluminum is generally more robust and, therefore, has more service years than polycarbonate. Polycarbonate is a less expensive option and is easily customizable.

Control Ranges
O2 » 0-60% in 0.1% increments and control tolerance
CO2 » 0-20% in 0.1% increment and control tolerance
Temperature control » ambient +4º to 40ºC
Humidity in glove box » adjustable to create non-condensing environment
Humidity in incubation box » saturated at temperature

 

Sizes available

Aluminum sizes, internal workspace:      
1 person (two glove ports): 41”Lx23”Dx35”H 1041x584x889mm
2 person (four glove ports): 59”Lx23”Dx35”H 1499x584x889mm
Polycarbonate sizes, internal workspace:      
Mini: 23”Lx23”Dx23”H 584x584x584mm
1 person: 41”Lx23”Dx23”H 1041x584x584mm
2 person: 59”Lx23”Dx23”H 1499x584x584mm

 

 

                  