Mandel Hopmepage
HomeTo Order
 

PipettesPipettorsPipette TipsAccessoriesAutomated Liquid Handlers

InjectorsFraction CollectorsPumps & Tubing

   
Multiple Probe 215 Liquid Handler/Injector

Gilson’s flexible liquid handler and injector is engineered to improve throughput for drug discovery and drug metabolism laboratories. High-throughput capacity is ideal for parallel injection onto HPLC or LC/MS systems.

Cat. No. GA-25101311


Features:

  • Large-capacity, multiple-probe liquid handler processes four or eight samples simultaneously; also performs injection into four or eight parallel systems simultaneously
  • High-throughput automation of basic liquid handling tasks such as: sample transfer, dilutions, mixing, reagent addition and plate reformatting
  • Perfect for high-throughput injection onto FIA/MS, parallel HPLC and MUX systems using the optional 889 Multiple-Injection Module
  • Patented Dual Rail™ syringe drive technology allows for accurate use of one to eight syringes and probes to fit your requirements
  • Ideal for bulk reagent dispensing

Specifications:

Manufacturing Standards

Meets applicable safety and EMC certification standards; UL and CE certified

Arm Speed

X: >45.7 cm/sec (>18 in./sec)
Y: >40.6 cm/sec (>16 in./sec)

Communication Interface

RS-232 or GSIOC; Four inputs (contact closure, TTL, or open-collector), four relay outputs and one switched +24V DC 1A output

Injection Volume

5 µL–5 mL

Injection Reproducibility

<2.0% CV with 500-µL syringe and partial loop filling method; <5.0% CV with 500-µL syringe and total loop filling method

Liquid Handling

Reproducibility:
0.57% CV with 500 µL of water
Accuracy:
99.2% with 500 µL of water

Front Panel

8-character display, START and emergency STOP soft keys

Horizontal Motion Strength

X: 5 kg (11.1 lbs.)
Y: 7 kg (15.6 lbs.)

Injection Carryover†

<0.05%

Locator Plate Capacity

Up to five Code 200-Series racks or one Code 505 or 505H rack plus one Code 200-Series rack

Maximum Syringe Flow Rates for Water
(with eight syringes installed)

Syringe Size
(µL)

Max. Flow Rate
(mL/min)

100

0.42

250

0.80

500

2.11

1000

4.22

2500

8.40

5000

12.50

Maximum Syringe Flow Rates for Water
(with four syringes installed)

Syringe Size
(µL)

Max. Flow Rate
(mL/min)

100

0.75

250

1.50

500

4.25

1000

8.50

2500

16.75

5000

25.00

Power Requirements

Frequency: 50–60 Hz
Voltage: 100–120 and 200–240V, mains voltage fluctuations not to exceed ±10% of the nominal voltage
Current rating: 2.0A for 100–120V or 1.0A for 220–240V

Probe Positioning Performance

Accuracy: ±0.5 mm in X/Y dimensions, ±1 mm in Z dimension
Repeatability: ±0.25 mm in X/Y/Z dimensions

Probe Rinse

Through a dedicated rinse station for rinsing the inside and outside of the probes

Sampler Type

X/Y/Z with stationary rack design

Software

Via Gilson UniPoint™ System Software or TRILUTION™ Software

Syringe Capacity

100, 250 or 500 µL; 1, 2.5 or 5 mL

Syringe Pump

Integral high-precision, eight-piston syringe pump

Vertical Punch Strength

0.6 kg/probe (1.4 lbs./probe)

Dimensions (w x d x h)

97.8 x 61 x 55.8* cm (38.5 x 24 x 22* in.)
*Maximum height. Z-arm height is adjustable to accommodate vessel heights between 1 and 150 mm (dependent on installed Z-arm).

Weight

39.9 kg (89 lbs.)

  Privacy Policy | Comments
Mandel Contact Us Mandel Homepage