Mandel Hopmepage
HomeTo Order
 

Bioluminescence ImagingBOD AnalysisCOD AnalysisCombustion ICGamma CountersMicroplate ReadersMoisture MetersSpectroscopySulfur / Chlorine / HalogenTAN / TBNTestingThermal AnalysisTitration and PHTOC AnalyzersTube Luminometers

AA-6200 Atomic Absorption Spectrophotometer Shimadzu
Cat. No. SZ-206-50000-36

Shimadzu's new double beam AA-6200 atomic absorption spectrophotometer recombines high performance and affordability. The double beam system provides the superior baseline stability expected from high performance optical systems at an affordable price. Use of AtomicA's Windows®-based software Wizard function provides easy operation for system control and data processing. The AA-6200 uses the least linear bench space of any atomic absorption spectrophotometer in the world. In spite of its compactness, the performance and capability is superior. In fact, the AA-6200 outperforms other atomic absorption instruments many times its physical size.

Features

Easy Operation

Use of WindowsTM software provides easy operation for system control and data processing. The Wizard function guides the user through the entire analytical procedure. Worksheets permit the experienced user direct access to the all the parameter's settings.

Compactness

Shimadzu AA-6200 uses one of the least linear bench space of any Atomic Absorption Spectrophotometers in the world. In spite of its compactness, the performance has not been compromised. In fact, the AA-6200 outperforms other atomic absorption instruments many times it's physical size.

Double Beam & D2

The double beam sytem provides superior baseline stability expected from high performance optical systems. The BGC-D2(Deterium Background Correction) Compensates for matrix interferences.

Affordable

This affordable double beam AA-6200 is designed and manufactured to meet your laboratory needs. The instrument offers not only an affordable solution to your analytical needs and requirements, but it also provides features usually available only on high-end instruments.

Specifications

AA-6200
Optics Double Beam (chopper mirror)
Monochromator Abbration corrected Czerny-Turner monochromator
Holographic grating (1,600 lines/mm)
Wavelength range 190 to 900 nm
Automated wavelength selection
Slit 0.2nm, 0.7nm Manual setting
Background Correction D2-Lamp method
Lamp Turret 2-lamps simultaneously lit (manual turret)
Lamp Mode Emission, Non-BGC, BGC-D2
Frequency 100Hz
Nebulizer Nebulizer integrated impact bead and jacket tip
Pt/lr capillary
Chamber Polypropylene
Burner Fixed back/foward position and burner height
(simply switching of Air/C2H2 burner)
Titanium 10cm slot burner(optional high temperature burner)
Gas Control Manual Seetting of flow rate
Automatic Air/N20 switching system
Safety Gas Pressure monitoring to prevent flashback
Automatic flame monitoring
Safety interlock for misuse of burner
Automatic flame extinguish when power failure
Ignition Push ignite button
Software Software base on MS-WindowsTM
Dimensions, weight 690 (W) x 370 (H) x 425 (D) mm, 38 kg
Power requirements AC220V, 230V, 50/60HZ, 300VA
(Requires transformer for AC 115V)
(Certificaiton of CE marking)
Ambient Temperature and humidity range Temperature: 10 ~ 35°C
Humidity: 45 ~ 80% (less than 70% when temperature is greater than 30°C)

 

 

  Privacy Policy | Comments
Mandel Contact Us Mandel Homepage