The Product of Customer Feedback
The ultimate is flexible sipper design from Shimadzu now allows the use of any supplier's flow cell. These new sippers can also be converted to any other type. That means that a micro
sipper without temperature control, can be converted to a water-jacketed type with a standard size flow cell. These sippers connect to the standard sample compartment of the UV-1601 and
Bio-Spec®-1601 for stand alone use. Plus, with Windows® -based software, the sippers and UV-1601PC, 2401PC and 2501PC can be controlled from your PC.
You asked and we listened...
Since these sippers are syringe-type pumps, tubing problems associated with peristaltic pumps have been eliminated. The syringe sippers are lightweight and free-standing with a small
footprint.
|
Sipper Type
|
Regular
|
Water Jacketed
|
Micro
|
Micro-Water Jacketed
|
|
Flow Cell Type
|
L-Type
|
C-Type
|
U-Type
|
CU-Type
|
|
Cell Capacity
|
520 uL
|
520 uL
|
30 uL
|
3 uL
|
|
Pathlength
|
10 mm
|
10 mm
|
10 mm
|
10 mm
|
|
Minimum Volume
|
0.8 mL
|
0.8 mL
|
60 uL
|
60 uL
|
|
Typical Volume
|
1.5 mL
|
1.5 mL
|
120 uL
|
120 uL
|
|
Speed of Pump
|
1.2, 0.6, 0.3, 0.2 ml/min
|
1.2, 0.6, 0.3, 0.2 ml/min
|
1.2, 0.6, 0.3, 0.2 ml/min
|
1.2, 0.6, 0.3, 0.2 ml/min
|
|
Sipping Time
|
10 - 60 S
|
10 - 60 S
|
1 - 60 S
|
1 - 60 S
|
|
Sipping Volume
|
0.0 - 9.99 ml
|
0.0 - 9.99 ml
|
0.0 - 9.99 ml
|
0.0 - 9.99 ml
|
|
Purging Time
|
10 - 60 S
|
10 - 60 S
|
10 - 60 S
|
10 - 60 S
|
|
Purging Volume
|
0.0 - 9.99 ml
|
0.0 - 9.99 ml
|
0.0 - 9.99 ml
|
0.0 - 9.99 ml
|
|
Dwell Time
|
0 - 99 S
|
0 - 99 S
|
0 - 99 S
|
0 - 99 S
|
|
Number of Rinses
|
0 to 6
|
0 to 6
|
0 to 6
|
0 to 6
|
|
Carryover
|
< 1%
|
< 1%
|
< 1%
|
< 1%
|
|
Manual Mode
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Wavelength Range (nm)
|
190 to 1100
|
190 to 1100
|
190 to 1100
|
190 to 1100
|
|
Temp. Control
|
N/A
|
Water Bath
|
N/A
|
Water Bath
|
|
Temp. Range
|
Ambient
|
5 to 90
|
Ambient
|
5 to 90
|
|
Dead Volume
|
0.8 mL
|
0.8 mL
|
60 uL
|
60 uL
|
|
Software Control
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Sample Recovery
|
On or Off
|
On or Off
|
On or Off
|
On or Off
|
|
Power
|
100/220 V
|
100/220 V
|
100/220 V
|
100/220 V
|
|
Cat. # - Syringe Sipper plus sample Compartment Assembly
|
220-92488-00 (includes 220-92588)
|
220-92488-00 plus 202-30858-04
|
220-92489-00 (includes 220-92589)
|
220-92490-00 (includes 220-92590)
|
Standard System Requirements
For UV-1601PC: Kinetics or Photometric software version 2.8 or higher, and ROM version 1.9 are higher are required. For UV-2401/2501PC: Kinetics or Photometric software version 2.8 or