Syringe Sippers
Syringe Sippers | The Product of Customer Feedback

The Product of Customer Feedback

The ultimate is flexible sipper design from Shimadzu now allows the use of any supplier's flow cell. These new sippers can also be converted to any other type. That means that a micro sipper without temperature control, can be converted to a water-jacketed type with a standard size flow cell. These sippers connect to the standard sample compartment of the UV-1601 and Bio-Spec®-1601 for stand alone use. Plus, with Windows® -based software, the sippers and UV-1601PC, 2401PC and 2501PC can be controlled from your PC.

You asked and we listened...

Since these sippers are syringe-type pumps, tubing problems associated with peristaltic pumps have been eliminated. The syringe sippers are lightweight and free-standing with a small footprint.

Sipper Type Regular Water Jacketed Micro Micro-Water Jacketed
Flow Cell Type L-Type C-Type U-Type CU-Type
Cell Capacity 520 uL 520 uL 30 uL 3 uL
Pathlength 10 mm 10 mm 10 mm 10 mm
Minimum Volume 0.8 mL 0.8 mL 60 uL 60 uL
Typical Volume 1.5 mL 1.5 mL 120 uL 120 uL
Speed of Pump 1.2, 0.6, 0.3, 0.2 ml/min 1.2, 0.6, 0.3, 0.2 ml/min 1.2, 0.6, 0.3, 0.2 ml/min 1.2, 0.6, 0.3, 0.2 ml/min
Sipping Time 10 - 60 S 10 - 60 S 1 - 60 S 1 - 60 S
Sipping Volume 0.0 - 9.99 ml 0.0 - 9.99 ml 0.0 - 9.99 ml 0.0 - 9.99 ml
Purging Time 10 - 60 S 10 - 60 S 10 - 60 S 10 - 60 S
Purging Volume 0.0 - 9.99 ml 0.0 - 9.99 ml 0.0 - 9.99 ml 0.0 - 9.99 ml
Dwell Time 0 - 99 S 0 - 99 S 0 - 99 S 0 - 99 S
Number of Rinses 0 to 6 0 to 6 0 to 6 0 to 6
Carryover < 1% < 1% < 1% < 1%
Manual Mode Yes Yes Yes Yes
Wavelength Range (nm) 190 to 1100 190 to 1100 190 to 1100 190 to 1100
Temp. Control N/A Water Bath N/A Water Bath
Temp. Range Ambient 5 to 90 Ambient 5 to 90
Dead Volume 0.8 mL 0.8 mL 60 uL 60 uL
Software Control Yes Yes Yes Yes
Sample Recovery On or Off On or Off On or Off On or Off
Power 100/220 V 100/220 V 100/220 V 100/220 V
Cat. # - Syringe Sipper plus sample Compartment Assembly 220-92488-00 (includes 220-92588) 220-92488-00 plus 202-30858-04 220-92489-00 (includes 220-92589) 220-92490-00 (includes 220-92590)

Standard System Requirements

For UV-1601PC: Kinetics or Photometric software version 2.8 or higher, and ROM version 1.9 are higher are required. For UV-2401/2501PC: Kinetics or Photometric software version 2.8 or higher, and ROM version 1.5 or higher are required.