Together with Gilson Manometric Modules and Dynamic Mixers, these Pumps offer a cost-effective, robust solution for isocratic to gradient, analytical to preparative HPLC. Cat. No.
GF-360261 (305), GF-3602661 (306), GF-3602671 (307)
Features:
-
305/306 Pumps are designed for use in either isocratic or gradient HPLC, and offer a wide range of flow rates from 10 µL/min to 200 mL/min
-
307 Pump is designed primarily for research and QC/QA in the isocratic mode, and offers flow rates from 10 µL/min to 10 mL/min
-
305 and 307 models are fully programmable through a front panel keypad to provide system control capabilities; 306 model functions as a slave unit and is controlled by either a 305 Pump
or by Gilson UniPoint™ System Software
-
Smooth flows are enhanced by a separate, external pulse dampener with the 305 and 306 models and a built-in pulse dampener in the 307
-
Pumps heads are designed for quick and easy maintenance—piston seals, check valves and other parts can be replaced in a matter of minutes
-
Three Manometric Modules with different flow rate ranges are available for use with the 305 and 306 Pumps to minimize pressure fluctuations; the 307 includes a built-in Manometric
Module
-
Dynamic Mixers ensure efficient, problem-free mobile phase mixing
-
Can be configured for use in a sample prep GPC or GPC/SPE system
Specifications:
|
Manufacturing Standards
|
Meet applicable Safety and EMC certification standards; UL and CE certified
|
|
Pump
|
Reciprocating pump with single-piston interchangeable head, constant stroke and fast refill motion, internal pulse dampener, and pressure feedback
|
|
Accuracy
|
<±1%
|
|
Repeatability
|
<1%
|
|
Operating Modes
|
Constant flow rate (Flow), constant volume (Dispense) and time-based sequence (Program)
|
|
Flow Rate
|
305/306: 10 µL/min to 200 mL/min
307: 10 µL/min to 10 mL/min
|
|
Liquid-Contact Materials
|
316L stainless steel, titanium, sapphire, ruby, ceramic, PTFE, PCTFE, and HDPE
|
|
Power Requirements
|
Frequency: 50–60 Hz
Voltage: 100–120 or 220–240V; mains voltage fluctuations not to exceed ±10% of the nominal voltage
|
|
Front Panel (305/307)
|
Keypad and built-in help messages
|
|
Display Panel (305/307)
|
2 x 24-character LCD
|
|
Communication Interface (305/307)
|
RS-232 or GSIOC; four inputs, three (305) or four (307) relay outputs
|
|
Software
|
Via Gilson UniPoint™ System Software
|
|
Dimensions (w x d x h)
|
33 x 33 x 15 cm (13 x 13 x 6 in.)
|
|
Weight (with head)
|
305/306: 10 kg (22 lbs.)
307: 11.5 kg (25.4 lbs.)
|
|
Shipping Weight (with head)
|
305/306: 14.5 kg (32 lbs.)
307: 15.4 kg (34 lbs.)
|
|