The SPE 215 System is the optimal solution for high-throughput solid phase extraction and sample purification. It offers versatile application support through 96-well extraction plates and 1- and 3-mL SPE cartridges. Positive-pressure elution—via Gilson's "Integrated Sealing Foot Design"—provides more accurate and precise liquid transfers.

Cat. No. GF-25101322

Features:

  • Processes up to eight samples every five minutes or 96 samples in an hour; ideal for high-throughput sample cleanup applications
  • Automates virtually all SPE steps (condition, load, collect, wash, elute and dry down)
  • An automated solution for sample preparation, sample reconstitution and injection onto HPLC or LC/MS systems
  • Enables parallel cleanup, filtration and purification of combinatorial libraries and biological fluids
  • Select large volumes of one to nine solvents or reagents depending upon your application
  • Performs injection of up to eight samples in parallel with the addition of the optional 889 Multiple Injection Module

Specifications:

Manufacturing Standards Meets applicable safety and EMC certification standards; UL and CE certified
Arm Speed X: >45.7 cm/sec (>18 in/sec)
Y: >40.6 cm/sec (>16 in/sec)
Communication Interface RS-232 or GSIOC; Four inputs (contact closure, TTL or open-collector), four relay outputs and one switched, +24V DC, 1A output
Environmental Conditions Indoor use
Altitude: up to 2000 m
Temperature range: 5–40°C
Air pressure: 75–105 kPa
Pollution degree: 1 or 2, in accordance with IEC 66
Humidity: Maximum relative humidity 80% for temperatures up to 31°C, decreasing linearly to 50% relative humidity at 40°C
Front Panel 8-character display, START and emergency STOP soft keys
Horizontal Motion Strength X: 5 kg (11.1 lbs.)
Y: 7 kg (15.6 lbs.)
Locator Plate Capacity Up to five combined Code 200-Series Racks and Code 800-Series SPE Racks
Maximum Syringe Flow Rates for Water (with eight syringes installed)
Syringe Size
(µL)
Max. Flow Rate
(mL/min)
500 2.11
1000 4.22
2500 8.40
5000 12.50
Power Requirements Frequency: 50–60 Hz
Voltage: 100–120 or 220–240V; mains voltage fluctuations not to exceed ±10% of the nominal voltage
Current rating: 2.5A for 100–120V, or 1.4A for 220–240V
Probe Positioning Performance Accuracy: ±0.5 mm in X/Y dimensions, ±1 mm in Z dimension
Repeatability: ±0.25 mm in X/Y/Z dimensions
Probe Rinse Through a dedicated rinse station for rinsing the inside and outside of the probes
Sampler Type X/Y/Z with stationary rack design
Software Via Gilson TRILUTION™ Software
Syringe Capacity 500 µL; 1, 2.5 or 5 mL
Syringe Pump External, integral, high-precision, eight-piston
Vertical Punch Strength 1.4 kg (3.1 lbs.) per probe at the default speed of 16.85 cm/sec
Dimensions (w x d x h) 97.8 x 61 x 64 cm (38.5 x 24 x 25.2 in.)
Weight 45.1 kg (99.5 lbs.)