HomeTo Order
 

AutomatedFiltrationFreeze DryersManualSyringe

Vacuum ConcentrationVials and Accessories

GD/X syringe filters

Whatman GD/X disposable syringe filters are the ideal choice for the preparation of hard-to-filter samples. The syringe filters have a pigment-free polypropylene housing to eliminate sample contamination and contain a unique prefiltration stack of Whatman GMF 150 (graded density) and GF/F glass microfibre media, which allows you to filter even the most difficult samples with less hand pressure. Compared to an unprotected membrane, GD/X syringe filters can process three to seven times more sample volume.

GMF 150 (graded density) and GF/F are produced from 100% borosilicate glass microfibre. The unique, graded density GMF 150 medium has a coarse top layer meshed with a fine layer beneath that retains particles to 1.0 µm. A GF/F filter then retains particles down to 0.7 µm. Below the prefilter stack is the final membrane.

This provides exceptionally good loading capacity with fast flow rates and avoids the build up of back pressure often experienced through "blocking" of an unprotected membrane.

Features and Benefits

  • 13 mm and 25 mm diameter syringe filters
  • 13 mm device for samples up to 10 mL and 25 mm device for samples larger than 10 mL
  • Sterile options available

Applications

Hard-to-filter heavily particulate laden samples

  • Dissolution testing
  • Content uniformity
  • Concentration analysis
  • Routine sample preparation
  • Food analysis
  • Environmental samples
  • Composite assay

Safety

High pressures can be obtained when using syringes. The smaller the syringe the higher the pressure that can be generated. As a general guide, the following pressures can be obtained by hand with the syringes indicated: 20mL- 30 psi; 10mL- 50 psi; 5mL- 75 psi; 3mL- 100 psi; 1m- 150 psi. Each user should determine the pressure they can generate by hand with a specific size syringe and take appropriate safety precautions not to exceed the recommended rating for the device used. If these limitations are exceeded, bursting of the device may occur.

Specifications

 

GD/X 13 mm

GD/X 25 mm

Housing

Polypropylene (pigment free)

Polypropylene (pigment free)

Filtration Area

1.3 cm2

4.6 cm2

Maximum Pressure

100 psi

75 psi

Volume ‘Hold Up’ Full Housing

0.5 mL

1.4 mL

with Air Purge

50 µL (approx)

250 µL (approx)

Dimensions

21.7 mm x 29.7 mm

21.7 mm x 29.7 mm

Weight

3 g (approx)

3 g (approx)

Flow Direction

Flow should enter from the inlet

Flow should enter from the inlet

Inlet Connection

Female luer lock

Female luer lock

Outlet Connection

Male slip luer

Male slip luer

Sterilization

Autoclave at 121ºC (131ºC max)

Autoclave at 121ºC (131ºC max)

 

at 15 psi for 20 minutes†

at 15 psi for 20 minutes†

Biosafe

All materials pass USP Class VI

All materials pass USP Class VI

Glass Microfiber

100% borosilicate

100% borosilicate

Prefiltration Media

GMF 150 10 µm : 1 µm

GMF 150 10 µm : 1 µm

 

GF/F 0.7 µm

GF/F 0.7 µm

Ordering Information - GD/X Syringe Filters

Catalog Number

Membrane†

Pore Size (µm)

Diameter (mm)

Quantity/Pack

13 mm GD/X – Non-Sterile

W-6870-1302

Nylon

0.2

13

150

W-6870-1304

Nylon

0.45

13

150

W-6871-1302

Nylon

0.2

13

1500

W-6871-1304

Nylon

0.45

13

1500

W-6872-1302

PVDF

0.2

13

150

W-6872-1304

PVDF

0.45

13

150

W-6873-1304

PVDF

0.45

13

1500

W-6874-1302

PTFE

0.2

13

150

W-6874-1304

PTFE

0.45

13

150

W-6875-1302

PTFE

0.2

13

1500

W-6875-1304

PTFE

0.45

13

1500

W-6876-1302

PSU

0.2

13

150

W-6876-1304

PSU

0.45

13

150

W-6878-1302

PP

0.2

13

150

W-6878-1304

PP

0.45

13

150

W-6880-1302

CA

0.2

13

150

W-6880-1304

CA

0.45

13

150

W-6882-1316

GF/A

1.6 *

13

150

W-6884-1310

GF/B

1.0*

13

150

W-6886-1312

GF/C

1.2*

13

150

W-6888-1327

GF/D1

2.7*

13

150

W-6894-1304

GMF1

0.45*

13

150

25 mm GD/X – Non-Sterile

W-6870-2502

Nylon

0.2

25

150

W-6870-2504

Nylon

0.45

25

150

W-6870-2550

Nylon

5.0

25

150

W-6871-2502

Nylon

0.2

25

1500

W-6871-2504

Nylon

0.45

25

1500

W-6871-2550

Nylon

5.0

25

1500

W-6872-2502

PVDF

0.2

25

150

W-6872-2504

PVDF

0.45

25

150

W-6873-2502

PVDF

0.2

25

1500

W-6873-2504

PVDF

0.45

25

1500

W-6874-2502

PTFE

0.2

25

150

W-6874-2504

PTFE

0.45

25

150

W-6875-2502

PTFE

0.2

25

1500

W-6875-2504

PTFE

0.45

25

1500

W-6876-2502

PSU

0.2

25

150

W-6876-2504

PSU

0.45

25

150

W-6878-2502

PP

0.2

25

150

W-6878-2504

PP

0.45

25

150

W-6879-2504

PP

0.45

25

1500

W-6880-2502

CA

0.2

25

150

W-6880-2504

CA

0.45

25

150

W-6881-2504

CA

0.45

25

1500

W-6882-2516

GF/A

1.6*

25

150

W-6883-2516

GF/A

1.6*

25

1500

W-6884-2510

GF/B

1.0*

25

150

W-6886-2512

GF/C

1.2*

25

150

W-6888-2527

GF/D1

2.7*

25

150

W-6890-2507

GF/F1

0.7*

25

150

W-6891-2507

GF/F1

0.7*

25

1500

W-6892-2515

934-AH

1.5*

25

150

W-6894-2504

GMF1

0.45*

25

150

W-6895-2504

GMF1

0.45*

25

1500

W-6904-2502

PES

0.2

25

150

W-6904-2504

PES

0.45

25

150

W-6905-2502

PES

0.2

25

1500

W-6905-2504

PES

0.45

25

1500

25 mm GD/XS – Sterile

W-6900-2502

PVDF

0.2

25

50

W-6900-2504

PVDF

0.45

25

50

W-6896-2502

PES

0.2

25

50

W-6896-2504

PES

0.45

25

50

W-6897-2502

PES

0.2

25

500

W-6897-2504

PES

0.45

25

500

W-6901-2502

CA

0.2

25

50

W-6901-2504

CA

0.45

25

50

W-6902-2504

GMF1

0.45*

25

50

† PP – Polypropylene

PSU – Polysulfone

PES – Polyethersulfone

PVDF – Polyvinylidene fluoride

PTFE – Teflon

CA – Cellulose acetate

GF – Glass filber

GMF - Glass microfiber

* Glass microfiber particle retention rating

1 Contains GMF 150 without the GF/F prefilter

 

 

  Privacy Policy | Comments